• 86-592-5250042
  • info@leesii.com
  • leesiifans
  • M.P.:+86 138 6012 0550

China Fans and Blowers Manufacturer:Leesii

Google+YouTubeTwitterFacebook
Leesii
Leesii
China Fans and Blowers Manufacturer
  • Home
  • About Us
    • Company Profile
    • Workshops & Equipments
    • Certificates
    • Leesii’s History
    • Contact Us
  • Products
    • Centrifugal Fans(for HVAC)
      • LFS-A,Single Inlet Centrifugal Fans-Forward Inclined-Direct Drive
      • LFS-E,Single Inlet Centrifugal Fans-Forward Inclined-Belt Drive
      • LFS-C,Single Inlet Centrifugal Fans-Forward Inclined-Belt Drive
      • LBS-A,Single Inlet Centrifugal Fans-Backward Inclined-Direct Drive
      • LBS-E,Single Inlet Centrifugal Fans-Backward Inclined-Belt Drive
      • LBS-C,Single Inlet Centrifugal Fans-Backward Inclined-Belt Drive
      • LBS-P,Centrifugal Plug Fans
      • LFD-A,Double Inlet Centrifugal Fans-Forward Inclined-Direct Drive
      • LFD-EL,Double Inlet Centrifugal Fans-Forward Inclined-Belt Dirve
      • LFD-EH,Double Inlet Centrifugal Fans-Forward Inclined-Belt Drive
      • LBD-E,Double Inlet Centrifugal Fans-Backward Inclined-Belt Drive
    • Centrifugal Fans (for Industrial)
      • LIR-B
      • LIR-D
      • LIHR-I,High Pressure Radial Blowers
      • LIHR-II
      • LISB Series
      • LIPB
      • LIB-B
      • LIB-D
      • LISA Series
      • LIPA
      • LIA-B
      • LIA-D
    • In-Line Centrifugal Fans
      • LBH-F
      • LBH-B
      • LBF-F
      • LBF-B
      • LBI
    • Fiberglass Reinforced Plastic Fans
      • FRPB Series ,FRP Medium Pressure Centrifugal Fans
      • HFRPB Series FRP High Pressure Blowers
    • Axial Fans
    • Mixed Flow Fans
    • Roof Exhaust Fans
    • Tunnel Fans
    • Jet fans
    • Silent Contra Fans
    • Parts&Accessories
  • Applications
  • Industries
  • Resources
    • Parts&Service
    • Case Studies
  • Blog
  • Contact Us
MENU CLOSE back  

FAQS

We are usually asked about:

Reducing the pressure of fan

1, Changes the pipe resistance curve, increases the resistance, changes the fan operating point

2, Poor manufacturing quality fan or fan of serious wear

3, The fan speed is reduced

4, Fans are working in the unstable

Remedy:

1, Adjusting the resistance curve of pipe, reducing resistance to change fan operating point

2, Overhaul fan

3, Increase fan speed

4, Adjusting fan work-space

Failure of adjustable ventilation system

1, Pressure gauge malfunction, failure or stuck valves, flow and pressure that can not be adjusted as needed

2, Due to the need for low flow, pipes get clogged and traffic drastically reduced or stopped, the fan unstable region (flying zone) work and reverse flow turbine rotor to counter the phenomenon.

Remedy:

1, To repair or replace the pressure gauge for valve reparation

2, If the Department of the need to reduce the flow, you should open the bypass valve, or reduce speed, such as line pipe plug should be cleaned.

Pressure is too low to discharge the large amount of traffic

1, Changed the gas composition, high gas temperature or reduced solid impurities contained in the gas to reduce the density of the gas

2, The intake pipe ruptured or poor sealing of pipe

Remedy:

1, Measuring the gas density and eliminating the cause of density’s decrease

2, Weld cracks or replace pipe flange gasket

Pressure is too high to discharge the small amount of traffi

Cause of failure:1, Changed the gas composition, low gas temperature or increased solid impurities contained in the gas to increase the density of the gas

2, Outlet pipes and valves are clogged by soil, soot and debris and intake pipes, valves or grille are clogged by dust, soot and debris.

3, The outlet pipe ruptured or poor sealing of pipe

4, Big damage of the sealing and the worn impeller blades

Remedy:

1. Measuring the gas density and eliminating the cause of density’s increase

2, To open a large outlet valves, or cleaning.

3, To open a large intake valves, or cleaning.

4, Welding cracks or replace pipe flange gasket

Some common problems are given the solutions

1 . Bearing box rattling

① different heart fan shaft and motor shaft couplings installed crooked
② cabinet or friction with the impeller inlet
③ foundation is not solid steel degree
④ impeller or impeller loose rivet deformation
⑤ impeller shaft drive shaft loose, loose bolts or coupling
⑥ chassis with brackets, bearing box and bracket, bearing cover on the seat , such as loose coupling bolts
⑦ fan out of gas pipeline installation bad
⑧ rotor imbalance , fan blades wear

2. bearing temperature is too high

① bearing box rattling
② quality grease is not lit , deterioration, contain too much dust, sticky sand , dirt and other impurities
③ bearing cover, seat bolts clamping force is too large or too small
④ shaft with rolling bearing installation skew , after bearing two different heart
⑤ bearing damage

3. electrode current or temperature is too high

① when driving or throttle intake pipe gate is not closed tight
② traffic exceeds the specified value
③ fan conveying gas density is too large or sticky substances
④ motor input voltage is too low or single-phase power supply
⑤ coupling connection errors, aprons too tight or uneven gaps
⑥ affected by the impact of severe shock bearing box

You Must Pay Attention To The Notes In Selecting Fans

90% products of LEESII blower are designed according to customers’ performance requirements, each customer of LEESII blower will use the most suitable product .
But before purchasing, you should be attention to the following items that you must be aware.

Please try to provide us the following data, which maybe affect the design accuracy.
*Pressure: what is the required pressure?
*Air capacity: what is the required air capacity on the basis of enough pressure?
*Medium temperature: what is the temperature of the gas that passes through the blower? And what is the maximum temperature?
If you cannot provide the accurate temperature, please tell us the range of the temperature, which will help us for designing the blower.
*Altitude: the air density and atmospheric pressure will change while the altitude changes, which will make the blower performance different. One blower will output different at low altitude and high altitude. So ,please try to provide us the altitude of site where the blowers will be used .Usually ,the technicians from the project owner and the design company can provide this data .If not ,please give us a approximate altitude, which will help us for designing the blower.
*Voltage & frequency: what is the voltage and frequency of the site where the blowers will be used?
*If the blower is an ordinary one, please provide the rotation direction and outlet angle.The following information will help us to learn more about the fan operation conditions, which maybe affect the fan’s reliability, lifetime and safety.
*What is the maximum and minimum temperature of the environment where the fan locates?
1.Is there dust in the fan transported gas? what is the dust loading?
2.Is there corrosive gas in the fan transported gas? If possible, please provide gas composition.
3.Is there inflammable and explosive gas or dust in the conveyed gas of the fan or the environment where the fans locates?

Didn’t find the answer?

Send messageclear

Testimonials:

  • We took an LEESII unit on trial and subsequently ordered 15 units,which says it all as regards our satisfaction with the product.
    Frank Lee
    MASTERKONG,Setter Training Manager
  • The LEESII fans enables us to maximise throughput with no issue relating to the drying function and it’s also easy to switch product runs
    Erik Emanuelsson
    Chang Gung Memorial Hospital,Project Manager
  • We took an LEESII unit on trial ans subsequently ordered 15 units,which says it all as regards our satisfactions with the product.
    Raaj Raja
    TPK,Setter Training Manager
  • LEESII has been flexible & accommodating to help us accomplish our operating objectives with regard to finding the correct air delivery patterns,volumes & velocities-all to good effect
    Stewart Chin
    C&D, Engineering Team Leader
  • LEESII understood our needs and supplied a package to satisfy them within a very tight time schedule
    Sim Leng
    JOEONE,Chief Technology Officer
  • LEESII has been with us from the start.The latest centrifugal fan satisfies all our requirements whilst also helping us to achieve system design improvements.
    Alex Zhang
    STEOTWOLVE,Design Engineer

Contact Info
Address:
No. 888, Chisong Road, Tulou Village, Fengnan Farm, Tong'an District,Xiamen City,Fujian Provice,China
Tel:
0086-592-5250042
Fax:
0086-592-5250046
Mobile:
0086-13860120550
Email:
info@leesii.com
Product
  • Centrifugal Fans(for HVAC)
  • Centrifugal Fans (for Industrial)
  • In-Line Centrifugal Fans
  • Fiberglass Reinforced Plastic Fans
  • Axial Fans
  • Mixed Flow Fans
  • Roof Exhaust Fans
  • Jet Fans
  • Silent Contra Fans
Blog
  • Couple drive
    What Are The Features of Double Inlet Centrifugal Fans
    31/08/2015
  • Axial Flow Blower Structure
    What Are The Key Features Of Axial Flow Blower?
    31/08/2015
  • Assembling a centrifugal fan
    What Are The Important Aspects of Centrifugal Fan Blades?
    31/08/2015
  • Industrial Centrifugal Blower Impeller Balancing
    Important Of Blower Impeller Balancing
    31/08/2015
Contact Us

Submitclear

Leesii
© Copyright 2015 Xiamen Leesii Industry and Trade Co.,Ltd.All rights reserved